A Contract Research Organization

| Filters | Cell Culture | Liquid Handling | Chromatography |

Chromatography
|Thin Layer Chromatography (TLC)|
|High Performance/High Pressure Liquid Chromatography (HPLC)|
|Fast Protein Liquid Chromatography (FPLC)|

Thin Layer Chromatography (TLC)

Catalog No.  
Description
Analtech 02011 Silica Gel

Silica Gel: Silica Gel G & GF UNIPLATES are the most widely used silica gel TLC plates. No organic substances are added to these products, thus making them compatible with sulfuric acid charring visualization.These plates are commonly scraped from the glass backing to isolate separated components for other analytical procedures. They are compatible with all organic solvents, however, they are not recommended for use in systems containing greater than 20% water because of the solubility of the gypsum binder in aqueous solutions. (For water tolerance see the GHL & GHLF series of plates.)The "G" stands for Gypsum and indicates that calcium sulfate hemihydrate (CaSO4·1/2H2O), a refined form of gypsum, has been included in the adsorption formulation. Gypsum functions as a binder, improving the cohesion of the adsorbent particles and increasing the adhesion of the layer to the glass substrate.The "F" indicates the presence of a short wave UV indicator that is fluorescent at 254 nm.· Fluorescent indicator has green fluorescence at 254 nm· Soft Layers with gypsum binder enable easy scraping of bands from plate· G & GF layers contain no organic materials.
250 um 20x20cm (25 plates/box)

Baker-flex
4474-04
Cellulose Sheets
Cellulose PEI-F Sheets: Ready-to-use plastic sheets, 50 x 200 mm or 200 x 200 mm, with absorbent coating, which is abrasion-resistant and highly uniform; are easily cut to desired size and allow sample fraction to be cut rather than scraped. The silica gel and aluminum oxide sheets have coating approximately 200 microns (0.2 mm) thick, affording considerably larger sample capacity than thinner coatings commonly used for flexible TLC plates. Lightweight plastic substrate is unbreakable and resists attack by reagents and solvents. Offered with a variety of absorbent coatings, with and without binder and indicator which fluoresces under 254 nm radiation. Coatings are of high purity silica gel, aluminum oxide or cellulose powders. The inert binder and indicator used permit sulfuric acid heat treatment of silica gel and aluminum oxide chromatograms without charring. Contain inert binders. Coating thickness of approximately 100 microns (0.1 mm) .Contain no inert binder. Sheets with suffix “F” contain fluorescent indicator
Whatman
4861-820
Silica Gel
Silica Gel: Adsorption TLC Plates. Silica Gel, 10-12um particle size. For normal phase analytical TLC separations of moderate to strong polar compounds. With fluorescent indicator. Pore Size: 60A. Layer Thickness: 250um. Plate Size: 20x20cm. Quantity: 25
EMD Chemicals
16834-2
Sheets
TLC Sheets:

Specifications

Color test, Bleu VIF Organol

18-26hRf

Color test, Ceres black

40-50hRf

Color test, Ceres violet BRN

59-69hRf

d 50 (Laser diffraction, size distribution)

10-12µm

Layer thickness

165-235µm

Layer thickness deviation, per plate

40µm max

Pore volume (N2-isotherm)

0.74-0.84mL/g

Specific surface (BET, 5-point measurement)

480-540m²/g

 

EMD Chemicals
5560-4 

Sheets
TLC Sheets:

Specifications

Chromatographic test, cholesterine

28-36hRf

d 50 (Laser diffraction, size distribution)

10-12µm

Layer thickness

150-200µm

Layer thickness deviation, per plate

30µm max

Pore volume (N2-isotherm)

0.74-0.84mL/g

Specific surface (BET, 5-point measurement)

480-540m²/g

Steroid test, Hydrocortisone

42-52hRf

Steroid test, Methyltestosterone

16-26hRf

Steroid test, Reichstein S

30-40hRf

 
EMD Chemicals
5534-3
Sheets
TLC Sheets :

Specifications

Color test, Bleu VIF Organol

10-20hRf

Color test, Ceres black

30-45hRf

Color test, Ceres violet BRN

50-65hRf

d 50 (Laser diffraction, size distribution)

10-12µm

Layer thickness

165-235µm

Layer thickness deviation, per plate

35µm max

Pore volume (N2-isotherm)

0.74-0.84mL/g

Specific surface (BET, 5-point measurement)

480-540m²/g

 
Analtech
06031
Avicel F
TLC Plate: These plates are coated with AVICEL microcrystalline cellulose manufactured by the American Viscose division of FMC Corp. The adsorbent consists of regenerated alpha cellulose particles of nearly spherical shape and 50 micron mean diameter. Avicel F 250 um 5x20cm (25 plates/box).
EMD Chemicals
5729-6 
Plates
TLC Plates :

Specifications

Color test, Bleu VIF Organol

10-20hRf

Color test, Ceres black

30-45hRf

Color test, Ceres violet BRN

50-65hRf

Color test, Separation number

9.0 min

d 50 (Laser diffraction, size distribution)

10-12µm

Layer thickness

210-270µm

Layer thickness deviation, per plate

35µm max

Pore volume (N2-isotherm)

0.74-0.84mL/g

Specific surface (BET, 5-point measurement)

480-540m²/g

Steroid test, Hydrocortisone

20-35hRf

Steroid test, Methyltestosterone

40-46hRf

Steroid test, Reichstein S

30-37hRf

Steroid test, Separation number

10.5 min

 
Baker
7013-04
Plate
TLC Plate: Precoated Glass Plate - Octadecylsilane (C18) Reversed Phase Bonded to SilicaGel (approx. 20-µm Particle Size), 200-µm Hard-surfaced Analytica For Laboratory, Research or Manufacturing Use. BAKER Pre-Coated Hard Layer TLC Plates are convenient and reliable for thin layer chromatography. Plates are sealed to exclude moisture and have a convenient hard surface for writing and ease of handling. The package contains plates coated with Reversed Phase, Octadecyl Silica (C18) Si-C18F (200 um Analytical Layer) with a fluorescent indicator.
 
Sigma-Aldrich Z148687-4EA Plate
TLC Plate: Thin-layer chromatography (TLC) plates for adsorption, partition, and ion-exchange techniques. Six media choices with glass, polyester, and aluminum backings. Silica-based adsorbent layers in Sigma-Aldrich TLC plates incorporate a polymeric binder; highly purified silica gel plates incorporate a gypsum/polymer binder. Silica gel - for weakly to strongly polar separations, pore size 60 Å. High purity silica gel - acid washed for separation of aflatoxins. Cellulose - for partition chromatography, (SigmaCell Type 100 Cellulose). Cellulose PEI - for separation of weak anions (amino acids, peptides) PEI plates may turn slightly yellow, affecting separation. Pre-develop plates in distilled water to minimize yellow color. Chiral silica - for separation of optically active isomers by ligand exchange, pore size 60Å.